Control Board Overview
E-S 500 / 502 Classic Series Instruction Manual
5.7
!
CAUTION! Do not run 110V AC power direct to the
board. This will cause permanent damage to both
boards and void your warranty. Caution!
Display
Indicators:
Lower right hand “dots” flashing normal pace:
Awaiting command / normal operation
Lower right hand “dots” flashing rapidly:
Safety terminal triggered / lacks connection
EL: Sending voltage to EL terminals (electric lock)
OP: Opening cycle
AU: Auto-reclose countdown
CL: Closing cycle
Buzzer/
Obstructions:
If the gate(s) come in contact with an obstruction
the gate(s) will reverse direction for 2 seconds
and stop to allow the obstacle to be cleared from
the gate path.
If the gate(s) obstructs 3 times in a row the gate(s)
will go into a hard shutdown mode and a buzzer
alarm will sound. At this point no accessories or
remotes will be able to activate the gate opener
until the gate opener is reset by disconnecting
primary power (transformer) and secondary
power (back up batteries - if applicable).