Programming Gate Run Times
In this stage, your control board will memorize where your limits are (identified by limit
switches, positive stops or both) in both opening and closing phases. Also if the auto-close
feature is activated it will learn the user specified pause time.
FOR SAFETY PURPOSES—your opener will not run until this step is completed
1. Release the operator gears using the manual release process. Once released, manually move the
gate(s) half way between the open and close stop points.
2. Relock the operator gears at the half way point
through its cycle.
3. Verify your operator control board is showing
on the LED display by touching the TWO reset
pins as in the graphic below.
HINT: Using a flat head screwdriver, place it between
the two pins and turn until contact is made with both.
4. Press and hold down P2 until the LED display shows
the A parameter and the relevant number appear in the
LED display.
5. Give an OPEN A command. This can be done with any opening device (keypad, push button,
etc…) wired into OPEN A and COM or using the transmitter. You can also briefly (one second or
less) jump OPEN A and COM with a wire. This will begin your gate in the CLOSING
DIRECTION and the LED display will read “Pr”.
IMPORTANT: If the gate(s) begin to open
rather than close, the gate(s) must be stopped with a reset pulse.
You can either:
Touch the TWO pins of the JMP “RESET” using a screwdriver OR
Disconnect all power (transformer and backup battery)
Then switch the wires leading into APM1-CHM1 (if Dual Operator APM2-CHM2 also) and then
begin programming again.