5. When the closing stop point or limit switch is reached, the motor pauses for approximately 2
seconds, and then restarts with a total opening maneuver to the opening stop point or limit
switch.
6. When the full open stop or limit switch is reached the gate(s) will stop.
7. Wait for the amount of time you would like your gate(s) to pause for (up to 4 minutes) during
normal operation before automatically re-closing and then signal your opener using an OPEN A
contact or transmitter signal to close the gate(s). The gate(s) will then return to closed and pro-
gramming will be complete.
Even if your auto close is off you must still set a pause time, the pause time
will not be used in normal gate operation.
4.5
Dual gates are programmed
simultaneously. Move both
of the leafs to the same
starting position and both
leafs will move together
through the same
programming sequence.
There is a slight starting
delay on the slave side.