Temporary Safety Jumpers & Dip Switch Settings
E-S 500 / 502 Classic Series Instruction Manual
3.4
If you are not using a safety
device like a photo eye or safety
loop the Photocell terminal must
remain jumped to the GND
terminal.
If you are using a SINGLE gate
installation the LIMIT 2 terminals
must remain jumped together.
For a DUAL gate jumpers must be
removed from limit terminals and
limit switch wires inserted.
!
IMPORTANT: We recommend before turning the gate
opener on for the first time to have dip switch 1 OFF. If
the dip switch is set to on, the gate will autoreclose
after turning it on without any intentional activation on
your part.
ON: Auto-close on (the gate will re-close
from the open position after a time set in
the programming section)
OFF: Auto-Close off
ON: Dual gate opener (2 motors)
OFF: Single gate opener (1 motor)
1.
2.
Dip Switches—To change either dip switch you must turn the
power off before changing the setting.