The Estate Swing E-S 500 comes with 1) 24V transformer. The transformer supplied
has 2 screw terminals to connect to. You may locate the transformer up to 200’
away from the control board using 16 gauge, 2 conductor stranded direct burial
low voltage wire. Do not use solid core wire.
Insert the two wires from the transformer into the two TRAN terminals on the
control board. The wires are not polarized, there is no positive or negative. DO
NOT SPLICE THE POWER CABLE WIRE.
Plug the transformer into a 110 V AC outlet.
The transformer is not weather proof and must be kept in a covered area. Plug
covers are available from your dealer, contact 1-800-640-GATE for a dealer in
your area.
Two 12V DC batteries (Max 5 a/h per battery) may be run in series as backup to
the 24V transformer power. Running two 12V batteries in series creates a 24V
system, you cannot run them in parallel (see diagram above)
When you install new batteries - manually open the gate and allow the batteries
to charge for 12 hours through the system before using the gate opener.
!
Never run 110VAC power directly to the Estate Swing.
This will destroy the Estate Swing control board.
Never connect the power wire with the transformer plugged in. Contact
between the two lead wires, even for a second, will destroy the transformer.
Transformers are only warranted if the internal fuse is not blown. If the fuse is
blown an outside factor (shorting, surge, water, etc) has caused the transformer
not to function.