E-S 1000D Series Instruction Manual
Troubleshooting
5.4
Gate stops mid cycle:
Check the P3 setting and make sure this is high enough. In windy conditions the gate might
obstruct so it is best to increase the P3 setting to avoid this problem in the future.
Check the battery voltage. Proper voltage should be between 12.5 - 13.8 and drop no
more than a quarter of a volt under load.
Disconnect accessories that may be triggering the gate a second time. The most frequent
issues are from exit sensors or other automatic opening devices.
Disconnect the receiver. In rare cases the receiver causes the gate to stop randomly.
Check the setback. The setback of the operator is important to correct operation due to
leverage the arm will have on the gate.
Check the gate itself for any changes in levelness and make sure the hinges are lubricated
properly.
Gate moves slower than normal:
Check the battery voltage. Proper voltage should be between 12.5 - 13.8 and drop no
more than a quarter of a volt under load.